WorldCat Identities

Shiota, Takahiro

Overview
Works: 9 works in 53 publications in 2 languages and 745 library holdings
Genres: Case studies 
Roles: Editor, Author
Classifications: QA76, 006.42
Publication Timeline
.
Most widely held works about Takahiro Shiota
 
Most widely held works by Takahiro Shiota
Filtering, segmentation, and depth by M Nitzberg( Book )

17 editions published in 1993 in English and Undetermined and held by 330 WorldCat member libraries worldwide

"Computer vision seeks a process that starts with a noisy, ambiguous signal from a TV camera and ends with a high-level description of discrete objects located in 3-dimensional space and identified in a human classification. This book addresses the process at several levels. First to be treated are the low-level image-processing issues of noise removaland smoothing while preserving important lines and singularities in an image. At a slightly higher level, a robust contour tracing algorithm is described that produces a cartoon of the important lines in the image. Thirdis the high-level task of reconstructing the geometry of objects in the scene. The book has two aims: to give the computer vision community a new approach to early visual processing, in the form of image segmentation that incorporates occlusion at a low level, and to introduce real computer algorithms that do a better job than what most vision programmers use currently. The algorithms are: - a nonlinear filter that reduces noise and enhances edges, - an edge detector that also finds corners and produces smoothed contours rather than bitmaps, - an algorithm for filling gaps in contours."--PUBLISHER'S WEBSITE
3D echocardiography by Takahiro Shiota( Book )

18 editions published between 2007 and 2014 in English and Undetermined and held by 80 WorldCat member libraries worldwide

This highly illustrated text on 3D echocardiography will provide the reader with a definitive viewpoint on the benefits of utilizing 3D echocardiography, a relatively new imaging tool in the clinical armamentarium. The contributing experts share the basic facts of 3D, as well as their personal experience in the field. This book reflects the latest technology in 3D echocardiographic imaging, this source is highly illustrated with top quality illustrations reflecting the advancement in diagnostic technology
Selected papers by David Mumford( Book )

10 editions published in 2010 in English and held by 71 WorldCat member libraries worldwide

Characterization of Jacobian varieties in terms of soliton equations by Takahiro Shiota( )

2 editions published in 1984 in English and held by 3 WorldCat member libraries worldwide

Transballoon intravascular ultrasound imaging during balloon angioplasty in animal models with coarctation and branch pulmonary stenosis( )

1 edition published in 1997 in English and held by 1 WorldCat member library worldwide

BACKGROUND: Intravascular ultrasound (IVUS) studies performed after balloon dilation provide a method for evaluating the adequacy of angioplastyature of associated changes in vessel walls. Previously, IVUS studies required the use of separate scanning catheters inserted independently before and after balloonangioplasty. We tested a 0.035-in, 30-MHz IVUS transducer wire that images from within commercially available 5F balloon dilation catheters. METHODS AND RESULTS: Seven stenoses were created in the left pulmonary artery (n = 3) and in the aortic isthmus (n = 4) in six lambs (weight, 3.4 to 12.5 kg). The balloon catheter selected was advanced across the stenotic area and the IVUS wire advanced in the guide lumen to the center of the balloon. Continuous IVUS images were obtained through balloons before, during, and after dilation. Transballoon imaging confirmed balloon location within the stenotic segment. Luminal diameters of stenotic and adjacent vessel segments before and after angioplasty by IVUS showed good correlation with angiographicmeasurements (r = .93, P less th. or = .001). After successful dilation, imaging during deflation allowed the assessment of vascular elastic recoil, mural dissection, and luminal size without requiring changes in balloon position. Repeat dilation could be undertaken and the inflation pressure and technique modified on the basis of the observed results. CONCLUSIONS: This transballoon IVUS system provides important on-line information about lumen diameter and wall structure for evaluation of angioplasty without the need for catheter changes, providing a method to possibly reduce the likelihood of excessive wall damage and to potentially reduce the number of angiograms required to accomplish and confirm results
Nonlinear image smoothing with edge and corner enhancement by M Nitzberg( Book )

1 edition published in 1990 in English and held by 1 WorldCat member library worldwide

Rinshō sanjigen shin'ekō : shōrei kara manabu nijigen shin'ekō tono hikaku by Takahiro Shiota( Book )

2 editions published in 2011 in Japanese and held by 1 WorldCat member library worldwide

Development of sandwich type laminated steel sheets by K Shirayama( Book )

1 edition published in 1986 in English and held by 0 WorldCat member libraries worldwide

 
Audience Level
0
Audience Level
1
  Kids General Special  
Audience level: 0.71 (from 0.52 for Rinshō sa ... to 1.00 for Developmen ...)

Filtering, segmentation, and depth
Alternative Names
Shiota, T.

Shiota Takahiro

Shioto, T.

Shioto, T. (Takahiro)

Takahiro Shiota

Takahiro Shiota Japanese mathematician

Takahiro Shiota japanischer Mathematiker

Takahiro Shiota Japans wiskundige

Takahiro Shiota matemático japonés

シオタ, タカヒロ

塩田隆比呂 数学者

Languages
Covers
3D echocardiographySelected papers