跳至内容
Fabrication and characterization of polypyrrole/glucose oxidase electrode on a microfabricated capillary electrophoresis chip 線上預覽
關閉線上預覽
正在查...

Fabrication and characterization of polypyrrole/glucose oxidase electrode on a microfabricated capillary electrophoresis chip

作者: Jayadeep Gullapalli
出版商: 2005.
論文: Thesis (M.S.)--University of Louisville, 2005.
版本/格式:   碩士/博士論文 : 碩士論文/博士論文 : 手稿   文檔資料 : 英語
資料庫:WorldCat
提要:
Research on lab-on-a-chip devices fabricated by traditional microfabrication techniques are gaining importance in the field of analytical chemistry. In particular there is an increasing demand for miniaturized biosensors based on enzymes owing to their applications in clinical analysis. With respect to Capillary Electrophoresis (CE) microchips, enzymes can impart a greater degree of selectivity. The technique of  再讀一些...
評定級別:

依據 1 評分 1 附有評論

更多類似這樣的

 

在圖書館查詢

&AllPage.SpinnerRetrieving; 正在查詢有此資料的圖書館...

詳細書目

資料類型: 碩士論文/博士論文, 手稿
文件類型: 圖書, 文檔資料
所有的作者/貢獻者: Jayadeep Gullapalli
OCLC系統控制編碼: 70259384
注意: Department of Electrical and Computer Engineering.
Vita.
"August 2005."
描述: xi, 119 leaves : ill. (some col.) ; 29 cm.
責任: by Jayadeep Gullapalli.

摘要:

Research on lab-on-a-chip devices fabricated by traditional microfabrication techniques are gaining importance in the field of analytical chemistry. In particular there is an increasing demand for miniaturized biosensors based on enzymes owing to their applications in clinical analysis. With respect to Capillary Electrophoresis (CE) microchips, enzymes can impart a greater degree of selectivity. The technique of electrochemical polymerization was used to immobilize glucose oxidase on the CE microchip. Polypyrrole was used an immobilization matrix. The second chapter describes the experimental procedure for the immobilization of glucose oxidase on the CE microchip device. A two-step procedure was employed, which involved a thin layer of polypyrrole followed by a thick layer of polypyrrole/glucose oxidase film. The third chapter deals with the results obtained using a CE microchip.

評論

讀者提供的評論

WorldCat讀者評論 (1)

Jayadeep Gullapalli

評論者是 p_joseph_kiran (WorldCat讀者所發佈的 2013-01-18) 極好 Permalink

Hi Jayadeep,

Its Me Joseph Kiran (LFJC) your friend, contact me on <a href="mailto:kinni23@yahoo.com">kinni23@yahoo.com</a>

Its Me Joseph Kiran (LFJC) your friend, contact me on <a href="mailto:kinni23@yahoo.com">kinni23@yahoo.com</a>

Its Me Joseph Kiran (LFJC) your...
再讀一些...  再讀一些...

  • 此評論對你是否有所裨益?
  •   
正在擷取GoodReads評論...
正在擷取DOGObooks的評論

標籤

所有的讀者標籤 (1)

檢視最熱門的標籤,呈現的形式是: 標籤我的最愛清單 | 標籤雲(tag cloud)

確認申請

你可能已經申請過這份資料。若還是想申請,請選確認。

連結資料


<http://www.worldcat.org/oclc/70259384>
library:oclcnum"70259384"
owl:sameAs<info:oclcnum/70259384>
rdf:typej.1:Thesis
rdf:typeschema:Book
schema:creator
schema:datePublished"2005"
schema:description"Research on lab-on-a-chip devices fabricated by traditional microfabrication techniques are gaining importance in the field of analytical chemistry. In particular there is an increasing demand for miniaturized biosensors based on enzymes owing to their applications in clinical analysis. With respect to Capillary Electrophoresis (CE) microchips, enzymes can impart a greater degree of selectivity. The technique of electrochemical polymerization was used to immobilize glucose oxidase on the CE microchip. Polypyrrole was used an immobilization matrix. The second chapter describes the experimental procedure for the immobilization of glucose oxidase on the CE microchip device. A two-step procedure was employed, which involved a thin layer of polypyrrole followed by a thick layer of polypyrrole/glucose oxidase film. The third chapter deals with the results obtained using a CE microchip."
schema:exampleOfWork<http://worldcat.org/entity/work/id/57472707>
schema:inLanguage"en"
schema:name"Fabrication and characterization of polypyrrole/glucose oxidase electrode on a microfabricated capillary electrophoresis chip"
schema:url

Content-negotiable representations

關閉視窗

請登入WorldCat 

没有帳號嗎?你可很容易的 建立免費的帳號.