Fire flow water consumption in sprinklered and unsprinklered buildings : an assessment of community impacts

Verfasser/in: Code Consultants, Inc.
Verlag: New York, NY : Springer, ©2012.
Serien: SpringerBriefs in fire.
Ausgabe/Format   E-Book : Dokument : EnglischAlle Ausgaben und Formate anzeigen
Datenbank:WorldCat
Zusammenfassung:
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book  Weiterlesen…
Bewertung:

(noch nicht bewertet) 0 mit Rezensionen - Verfassen Sie als Erste eine Rezension.

Themen
Ähnliche Titel

 

Online anzeigen

Links zu diesem Titel

Exemplar ausleihen

&AllPage.SpinnerRetrieving; Suche nach Bibliotheken, die diesen Titel besitzen ...

Details

Gattung/Form: Electronic books
Physisches Format Print version:
Fire flow water consumption in sprinklered and unsprinklered buildings.
Springer Verlag, [2012]
(OCoLC)843859396
Medientyp: Dokument, Internetquelle
Dokumenttyp: Internet-Ressource, Computer-Datei
Alle Autoren: Code Consultants, Inc.
ISBN: 9781461481096 1461481090
OCLC-Nummer: 854624336
Beschreibung: 1 online resource.
Inhalt: Introduction --
Community Selection --
Assessment of Fire Flow Fees --
Characteristic Set of Buildings --
Calculation of Fire Water Volume --
Calculation of Water Usage for Commissioning, Inspection, Testing, and Maintenance --
Fire Probability and Frequency --
Compiled Data (Probability and Volume) --
Calculation of Fire Fees --
American Water Works Association (AWWA).
Serientitel: SpringerBriefs in fire.
Verfasserangabe: Code Consultants, Inc.
Weitere Informationen:

Abstract:

Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage. The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable.

Rezensionen

Nutzer-Rezensionen
Suche nach GoodReads-Rezensionen
Suche nach DOGObooks-Rezensionen…

Tags

Tragen Sie als Erste Tags ein.
Anfrage bestätigen

Sie haben diesen Titel bereits angefordert. Wenn Sie trotzdem fortfahren möchten, klicken Sie auf OK.

Verlinkung


<http://www.worldcat.org/oclc/854624336>
library:oclcnum"854624336"
library:placeOfPublication
library:placeOfPublication
owl:sameAs<info:oclcnum/854624336>
rdf:typeschema:Book
schema:about
schema:about
schema:about
schema:about
schema:about
schema:about
schema:bookFormatschema:EBook
schema:contributor
schema:copyrightYear"2012"
schema:datePublished"2012"
schema:description"Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage. The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable."
schema:exampleOfWork<http://worldcat.org/entity/work/id/1374545342>
schema:genre"Electronic books."
schema:inLanguage"en"
schema:name"Fire flow water consumption in sprinklered and unsprinklered buildings an assessment of community impacts"
schema:publisher
schema:url<http://site.ebrary.com/id/10735503>
schema:url<http://lib.myilibrary.com?id=517017>
schema:url<http://search.ebscohost.com/login.aspx?direct=true&scope=site&db=nlebk&db=nlabk&AN=611903>
schema:url<http://dx.doi.org/10.1007/978-1-4614-8109-6>
schema:url
schema:workExample

Content-negotiable representations

Fenster schließen

Bitte in WorldCat einloggen 

Sie haben kein Konto? Sie können sehr einfach ein kostenloses Konto anlegen,.