skip to content
Hemodynamic waveform recognition Preview this item
ClosePreview this item
Checking...

Hemodynamic waveform recognition

Author: Thomas Ahrens
Publisher: Philadelphia : W.B. Saunders, ©1993.
Series: Saunders flipfacts.
Edition/Format:   Print book : EnglishView all editions and formats
Summary:

This manual emphasizes key concepts for interpreting haemodynamic waveforms such as pulmonary capillary wedge, CUP and arterial waveforms, and presents a quick and easy approach to the complexities  Read more...

Rating:

(not yet rated) 0 with reviews - Be the first.

Subjects
More like this

 

Find a copy online

Links to this item

Find a copy in the library

&AllPage.SpinnerRetrieving; Finding libraries that hold this item...

Details

Material Type: Internet resource
Document Type: Book, Internet Resource
All Authors / Contributors: Thomas Ahrens
ISBN: 0721643132 9780721643137
OCLC Number: 26587678
Notes: Includes index.
Description: xv, 198 pages : illustrations ; 16 cm.
Contents: Waveform generation; graph paper and scales; use of bedside monitors for obtaining values; ECG use with waveform interpretation; the pulmonary capillary wedge pressure (PCWP) and central venous pressure (CVP) - examples of atrial waveforms; ECG correlation with atrial waveforms; reading a CVP tracing; reading a PCWP tracking; abnormal PCWP and CVP (venous) waveforms; large A waves; loss of A waves; large V waves; ventricular waveforms; ECG correlation with ventricular waveforms; reading a right ventricular waveform; arterial waveforms; ECG correlation with arterial waveforms; reading a right ventricular waveform; arterial waveforms; ECG correlation with arterial waveforms; reading a pulmonary artery waveform; reading a systemic arterial waveform; respiratory artifact; airway pressure measurement as an aid to reading hemodynamic waveforms; end tidal CO2 (PETCO2) measurement as an aid to identifying end expiration; spontaneous breathing artifact; mechanical ventilation artifact; combined respiratory artifact; reading a CVP with spontaneous breathing artifact; reading a CVP with mechanical ventilation artifact; reading a PCWP with spontaneous breathing artifact; reading a PCWP with mechanical ventilation artifact; reading a pulmonary artery waveform with spontaneous respiration artifact; reading a pulmonary artery waveform in the patient on mechanical ventilation; interpreting systemic arterial pressures associated with mechanical ventilation; inverse ratio ventilation; blood pressure chances associated with spontaneous breathing; increase in blood pressure with mechanical ventilation; decrease in blood pressure with mechanical ventilation; solving the four most common errors in hemodynamic monitoring equipment necessary for hemodynamic monitoring; aero/balancing; leveling of the transducer/amplifier system; methods of leveling the transducer-amplifier system; calibration of the transducer/amplifier system; concept of damping; square wave test; measuring for laterations in damping; frequency response; damping coefficient; optimally damped waveform; underdamped waveforms; improving an underdamped waveform; overdamped waveforms; interpreting waveforms with artifact; correlation of the pulmonary artery diastolic pressure with the wedge pressure; Part contents.
Series Title: Saunders flipfacts.
Responsibility: Thomas S. Ahrens.

Reviews

User-contributed reviews
Retrieving GoodReads reviews...
Retrieving DOGObooks reviews...

Tags

Be the first.
Confirm this request

You may have already requested this item. Please select Ok if you would like to proceed with this request anyway.

Linked Data


Primary Entity

<http://www.worldcat.org/oclc/26587678> # Hemodynamic waveform recognition
    a schema:CreativeWork, schema:Book ;
   library:oclcnum "26587678" ;
   library:placeOfPublication <http://experiment.worldcat.org/entity/work/data/29220586#Place/philadelphia> ; # Philadelphia
   library:placeOfPublication <http://id.loc.gov/vocabulary/countries/pau> ;
   schema:about <http://dewey.info/class/616.10754/e20/> ;
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Topic/monitorage_hemodynamique> ; # Monitorage hémodynamique
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Topic/hemodynamics> ; # Hemodynamics
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Topic/monitoring_physiologic_methods> ; # Monitoring, Physiologic--methods
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Topic/critical_care_methods> ; # Critical Care--methods
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Thing/humans> ; # Humans
   schema:about <http://id.worldcat.org/fast/955044> ; # Hemodynamic monitoring
   schema:about <http://experiment.worldcat.org/entity/work/data/29220586#Topic/hemodynamique> ; # Hémodynamique
   schema:bookFormat bgn:PrintBook ;
   schema:copyrightYear "1993" ;
   schema:creator <http://viaf.org/viaf/102483230> ; # Thomas Ahrens
   schema:datePublished "1993" ;
   schema:exampleOfWork <http://worldcat.org/entity/work/id/29220586> ;
   schema:inLanguage "en" ;
   schema:isPartOf <http://experiment.worldcat.org/entity/work/data/29220586#Series/saunders_flipfacts> ; # Saunders flipfacts.
   schema:name "Hemodynamic waveform recognition"@en ;
   schema:productID "26587678" ;
   schema:publication <http://www.worldcat.org/title/-/oclc/26587678#PublicationEvent/philadelphia_w_b_saunders_1993> ;
   schema:publisher <http://experiment.worldcat.org/entity/work/data/29220586#Agent/w_b_saunders> ; # W.B. Saunders
   schema:url <http://www.gbv.de/dms/bowker/toc/9780721643137.pdf> ;
   schema:workExample <http://worldcat.org/isbn/9780721643137> ;
   umbel:isLike <http://bnb.data.bl.uk/id/resource/GB9491594> ;
   wdrs:describedby <http://www.worldcat.org/title/-/oclc/26587678> ;
    .


Related Entities

<http://experiment.worldcat.org/entity/work/data/29220586#Series/saunders_flipfacts> # Saunders flipfacts.
    a bgn:PublicationSeries ;
   schema:hasPart <http://www.worldcat.org/oclc/26587678> ; # Hemodynamic waveform recognition
   schema:name "Saunders flipfacts." ;
   schema:name "Saunders flipfacts" ;
    .

<http://experiment.worldcat.org/entity/work/data/29220586#Topic/critical_care_methods> # Critical Care--methods
    a schema:Intangible ;
   schema:name "Critical Care--methods"@en ;
    .

<http://experiment.worldcat.org/entity/work/data/29220586#Topic/monitorage_hemodynamique> # Monitorage hémodynamique
    a schema:Intangible ;
   schema:name "Monitorage hémodynamique"@fr ;
    .

<http://experiment.worldcat.org/entity/work/data/29220586#Topic/monitoring_physiologic_methods> # Monitoring, Physiologic--methods
    a schema:Intangible ;
   schema:name "Monitoring, Physiologic--methods"@en ;
    .

<http://id.worldcat.org/fast/955044> # Hemodynamic monitoring
    a schema:Intangible ;
   schema:name "Hemodynamic monitoring"@en ;
    .

<http://viaf.org/viaf/102483230> # Thomas Ahrens
    a schema:Person ;
   schema:familyName "Ahrens" ;
   schema:givenName "Thomas" ;
   schema:name "Thomas Ahrens" ;
    .

<http://worldcat.org/isbn/9780721643137>
    a schema:ProductModel ;
   schema:isbn "0721643132" ;
   schema:isbn "9780721643137" ;
    .


Content-negotiable representations

Close Window

Please sign in to WorldCat 

Don't have an account? You can easily create a free account.