skip to content
Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint Preview this item
ClosePreview this item
Checking...

Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint

Author: Matthew T Muller; Jose Rodriguez; William Marion; National Renewable Energy Laboratory (U.S.)
Publisher: Golden, CO : National Renewable Energy Laboratory, [2009]
Series: Conference paper (National Renewable Energy Laboratory (U.S.)), NREL/CP-520-45948.
Edition/Format:   eBook : Document : National government publication : EnglishView all editions and formats
Summary:
This paper examines the performance of a building-integrated photovoltaic (BIPV) roofing system commonly available to residential markets. In particular, polycrystalline Si PV roofing tiles were integrated with concrete roofing tiles in two mounting configurations being used by roofing contractors. In the first configuration, the tiles were directly mounted to the roof sheeting, allowing little to no airflow under  Read more...
Rating:

(not yet rated) 0 with reviews - Be the first.

Subjects
More like this

Find a copy online

Links to this item

Find a copy in the library

&AllPage.SpinnerRetrieving; Finding libraries that hold this item...

Details

Material Type: Document, Government publication, National government publication, Internet resource
Document Type: Internet Resource, Computer File
All Authors / Contributors: Matthew T Muller; Jose Rodriguez; William Marion; National Renewable Energy Laboratory (U.S.)
OCLC Number: 422780758
Notes: Title from PDF title screen (viewed Oct. 30, 2009).
"To be presented at the 34th IEEE Photovoltaic Specialists Conference, Philadelphia, Pennsylvania, June 7-12, 2009."
"June 2009."
Description: 1 online resource (9 pages) : illustrations.
Series Title: Conference paper (National Renewable Energy Laboratory (U.S.)), NREL/CP-520-45948.
Other Titles: Performance comparison of a building integrated photovoltaic roofing tile system in two mounting configurations
Responsibility: M.T. Muller, J. Rodriguez, and B. Marion.

Abstract:

This paper examines the performance of a building-integrated photovoltaic (BIPV) roofing system commonly available to residential markets. In particular, polycrystalline Si PV roofing tiles were integrated with concrete roofing tiles in two mounting configurations being used by roofing contractors. In the first configuration, the tiles were directly mounted to the roof sheeting, allowing little to no airflow under the PV modules. In the second configuration, furring strips were attached to the roof deck to create a counter-batten system to which the roofing and PV tiles mount. This counter-batten system provides an air gap between the roof deck and the PV/concrete, tiles which allows for convective cooling. A complete data acquisition system was applied to both mounting configurations and they were monitored for a summer period in Golden, Colorado. A performance comparison is presented for the systems while both are gauged against free-standing, rack-mounted polycrystalline Si PV modules. As expected, modules mounted directly to the deck operated at higher temperatures and produced less power than those on a counter-batten system, while both systems operated at higher temperatures than rack-mounted modules.

Reviews

User-contributed reviews
Retrieving GoodReads reviews...
Retrieving DOGObooks reviews...

Tags

Be the first.
Confirm this request

You may have already requested this item. Please select Ok if you would like to proceed with this request anyway.

Linked Data


Primary Entity

<http://www.worldcat.org/oclc/422780758> # Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint
    a schema:CreativeWork, schema:Book, schema:MediaObject ;
    library:oclcnum "422780758" ;
    library:placeOfPublication <http://id.loc.gov/vocabulary/countries/cou> ;
    library:placeOfPublication <http://experiment.worldcat.org/entity/work/data/311363492#Place/golden_co> ; # Golden, CO
    rdfs:comment "Warning: This malformed URI has been treated as a string - 'http://purl.access.gpo.gov/GPO/LPS116607";'" ;
    schema:about <http://experiment.worldcat.org/entity/work/data/311363492#Topic/architecture_and_energy_conservation_united_states> ; # Architecture and energy conservation--United States
    schema:about <http://experiment.worldcat.org/entity/work/data/311363492#Topic/roofing_tile_energy_conservation_united_states> ; # Roofing, Tile--Energy conservation--United States
    schema:about <http://id.worldcat.org/fast/1204155> ; # United States.
    schema:about <http://experiment.worldcat.org/entity/work/data/311363492#Topic/building_integrated_photovoltaic_systems_energy_conservation_united_states> ; # Building-integrated photovoltaic systems--Energy conservation--United States
    schema:about <http://id.worldcat.org/fast/813553> ; # Architecture and energy conservation
    schema:alternateName "Performance comparison of a building integrated photovoltaic roofing tile system in two mounting configurations" ;
    schema:bookFormat schema:EBook ;
    schema:contributor <http://experiment.worldcat.org/entity/work/data/311363492#Person/rodriguez_jose> ; # Jose Rodriguez
    schema:contributor <http://viaf.org/viaf/166713954> ; # William Marion
    schema:contributor <http://viaf.org/viaf/153668500> ; # National Renewable Energy Laboratory (U.S.)
    schema:creator <http://experiment.worldcat.org/entity/work/data/311363492#Person/muller_matthew_t> ; # Matthew T. Muller
    schema:datePublished "2009" ;
    schema:description "This paper examines the performance of a building-integrated photovoltaic (BIPV) roofing system commonly available to residential markets. In particular, polycrystalline Si PV roofing tiles were integrated with concrete roofing tiles in two mounting configurations being used by roofing contractors. In the first configuration, the tiles were directly mounted to the roof sheeting, allowing little to no airflow under the PV modules. In the second configuration, furring strips were attached to the roof deck to create a counter-batten system to which the roofing and PV tiles mount. This counter-batten system provides an air gap between the roof deck and the PV/concrete, tiles which allows for convective cooling. A complete data acquisition system was applied to both mounting configurations and they were monitored for a summer period in Golden, Colorado. A performance comparison is presented for the systems while both are gauged against free-standing, rack-mounted polycrystalline Si PV modules. As expected, modules mounted directly to the deck operated at higher temperatures and produced less power than those on a counter-batten system, while both systems operated at higher temperatures than rack-mounted modules."@en ;
    schema:exampleOfWork <http://worldcat.org/entity/work/id/311363492> ;
    schema:genre "National government publication"@en ;
    schema:genre "Government publication"@en ;
    schema:inLanguage "en" ;
    schema:isPartOf <http://experiment.worldcat.org/entity/work/data/311363492#Series/conference_paper> ; # Conference paper ;
    schema:isPartOf <http://experiment.worldcat.org/entity/work/data/311363492#Series/conference_paper_national_renewable_energy_laboratory_u_s> ; # Conference paper (National Renewable Energy Laboratory (U.S.)) ;
    schema:name "Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint"@en ;
    schema:productID "422780758" ;
    schema:publication <http://www.worldcat.org/title/-/oclc/422780758#PublicationEvent/golden_co_national_renewable_energy_laboratory_2009> ;
    schema:publisher <http://experiment.worldcat.org/entity/work/data/311363492#Agent/national_renewable_energy_laboratory> ; # National Renewable Energy Laboratory
    schema:url <http://purl.access.gpo.gov/GPO/LPS116607> ;
    schema:url "http://purl.access.gpo.gov/GPO/LPS116607";" ;
    wdrs:describedby <http://www.worldcat.org/title/-/oclc/422780758> ;
    .


Related Entities

<http://experiment.worldcat.org/entity/work/data/311363492#Agent/national_renewable_energy_laboratory> # National Renewable Energy Laboratory
    a bgn:Agent ;
    schema:name "National Renewable Energy Laboratory" ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Person/muller_matthew_t> # Matthew T. Muller
    a schema:Person ;
    schema:familyName "Muller" ;
    schema:givenName "Matthew T." ;
    schema:name "Matthew T. Muller" ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Person/rodriguez_jose> # Jose Rodriguez
    a schema:Person ;
    schema:familyName "Rodriguez" ;
    schema:givenName "Jose" ;
    schema:name "Jose Rodriguez" ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Series/conference_paper> # Conference paper ;
    a bgn:PublicationSeries ;
    schema:hasPart <http://www.worldcat.org/oclc/422780758> ; # Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint
    schema:name "Conference paper ;" ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Series/conference_paper_national_renewable_energy_laboratory_u_s> # Conference paper (National Renewable Energy Laboratory (U.S.)) ;
    a bgn:PublicationSeries ;
    schema:hasPart <http://www.worldcat.org/oclc/422780758> ; # Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint
    schema:name "Conference paper (National Renewable Energy Laboratory (U.S.)) ;" ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Topic/architecture_and_energy_conservation_united_states> # Architecture and energy conservation--United States
    a schema:Intangible ;
    schema:hasPart <http://id.loc.gov/authorities/subjects/sh85006885> ;
    schema:name "Architecture and energy conservation--United States"@en ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Topic/building_integrated_photovoltaic_systems_energy_conservation_united_states> # Building-integrated photovoltaic systems--Energy conservation--United States
    a schema:Intangible ;
    schema:hasPart <http://id.loc.gov/authorities/subjects/sh96007020> ;
    schema:name "Building-integrated photovoltaic systems--Energy conservation--United States"@en ;
    .

<http://experiment.worldcat.org/entity/work/data/311363492#Topic/roofing_tile_energy_conservation_united_states> # Roofing, Tile--Energy conservation--United States
    a schema:Intangible ;
    schema:hasPart <http://id.loc.gov/authorities/subjects/sh85115328> ;
    schema:name "Roofing, Tile--Energy conservation--United States"@en ;
    .

<http://id.worldcat.org/fast/1204155> # United States.
    a schema:Place ;
    schema:name "United States." ;
    .

<http://id.worldcat.org/fast/813553> # Architecture and energy conservation
    a schema:Intangible ;
    schema:name "Architecture and energy conservation"@en ;
    .

<http://viaf.org/viaf/153668500> # National Renewable Energy Laboratory (U.S.)
    a schema:Organization ;
    schema:name "National Renewable Energy Laboratory (U.S.)" ;
    .

<http://viaf.org/viaf/166713954> # William Marion
    a schema:Person ;
    schema:familyName "Marion" ;
    schema:givenName "William" ;
    schema:name "William Marion" ;
    .

<http://www.worldcat.org/title/-/oclc/422780758>
    a genont:InformationResource, genont:ContentTypeGenericResource ;
    schema:about <http://www.worldcat.org/oclc/422780758> ; # Performance comparison of a BIPV roofing tile system in two mounting configurations : preprint
    schema:dateModified "2018-09-19" ;
    void:inDataset <http://purl.oclc.org/dataset/WorldCat> ;
    .


Content-negotiable representations

Close Window

Please sign in to WorldCat 

Don't have an account? You can easily create a free account.