pular para conteúdo
The r-unit at 320 and 160 Mev Ver prévia deste item
FecharVer prévia deste item
Checando...

The r-unit at 320 and 160 Mev

Autor: Edwin M McMillan; Wade Blocker; Robert W Kenney; U.S. Atomic Energy Commission.; Lawrence Radiation Laboratory.
Editora: Oak Ridge, Tenn. : U.S. Atomic Energy Commission, Technical Information Service, 1950.
Séries: UCRL (Series), 1004.
Edição/Formato   Livro : Publicação de governo nacional : InglêsVer todas as edições e formatos
Base de Dados:WorldCat
Resumo:
The r-unit is used today in at least two different ways: as a measure of radiation dosage, and as a measure of x-ray intensity. The meaning of the former is fairly well defined in terms of energy absorbed per gram of tissue, and the standard thimble chambers are calibrated to read in these terms. The meaning of the latter is much less clear. As originally defined, the r-unit referred to the ionization in air due to  Ler mais...
Classificação:

(ainda não classificado) 0 com críticas - Seja o primeiro.

Assuntos
Mais como este

 

Encontrar uma cópia na biblioteca

&AllPage.SpinnerRetrieving; Encontrando bibliotecas que possuem este item...

Detalhes

Formato Físico Adicional: Online version:
McMillan, Edwin M. (Edwin Mattison), 1907-
R-unit at 320 and 160 Mev.
Oak Ridge, Tenn. : U.S. Atomic Energy Commission, Technical Information Service, 1950
(OCoLC)852767089
Tipo de Material: Publicação do governo, Publicação de governo nacional
Tipo de Documento: Livro
Todos os Autores / Contribuintes: Edwin M McMillan; Wade Blocker; Robert W Kenney; U.S. Atomic Energy Commission.; Lawrence Radiation Laboratory.
Número OCLC: 796815662
Notas: "November 10, 1950."
Work performed at the Radiation Laboratory, University of California.
Descrição: 5 p. ; 28 cm.
Título da Série: UCRL (Series), 1004.
Outros Títulos: Technical Report Archive & Image Library (TRAIL)
Responsabilidade: By Edwin M. McMillan, Wade Blocker [and] Robert W. Kenney/

Resumo:

The r-unit is used today in at least two different ways: as a measure of radiation dosage, and as a measure of x-ray intensity. The meaning of the former is fairly well defined in terms of energy absorbed per gram of tissue, and the standard thimble chambers are calibrated to read in these terms. The meaning of the latter is much less clear. As originally defined, the r-unit referred to the ionization in air due to secondary electrons in equilibrium with the primary beam of x-rays. With low-energy x-rays equilibrium is easily attained since the range of the secondaries is small compared with the absorption distance of the primaries in air, but with high-energy-x-rays this is no longer true. Since a clearly defined equilibrium no longer exists, the old definition must be abandoned and the question remains: what should the r-unit mean in connection with the intensity of a beam of high-energy x-rays?

Críticas

Críticas contribuídas por usuários
Recuperando críticas GoodReas...
Recuperando comentários DOGObooks

Etiquetas

Seja o primeiro.

Ítens Similares

Assuntos Relacionados:(2)

Confirmar esta solicitação

Você já pode ter solicitado este item. Por favor, selecione Ok se gostaria de proceder com esta solicitação de qualquer forma.

Dados Ligados


<http://www.worldcat.org/oclc/796815662>
library:oclcnum"796815662"
library:placeOfPublication
library:placeOfPublication
rdf:typeschema:Book
rdf:valueUnknown value: ngp
rdf:valueUnknown value: gpb
rdfs:seeAlso
schema:about
schema:about
schema:about
schema:contributor
schema:contributor
schema:contributor
schema:contributor
schema:creator
schema:datePublished"1950"
schema:description"The r-unit is used today in at least two different ways: as a measure of radiation dosage, and as a measure of x-ray intensity. The meaning of the former is fairly well defined in terms of energy absorbed per gram of tissue, and the standard thimble chambers are calibrated to read in these terms. The meaning of the latter is much less clear. As originally defined, the r-unit referred to the ionization in air due to secondary electrons in equilibrium with the primary beam of x-rays. With low-energy x-rays equilibrium is easily attained since the range of the secondaries is small compared with the absorption distance of the primaries in air, but with high-energy-x-rays this is no longer true. Since a clearly defined equilibrium no longer exists, the old definition must be abandoned and the question remains: what should the r-unit mean in connection with the intensity of a beam of high-energy x-rays?"
schema:exampleOfWork<http://worldcat.org/entity/work/id/1367645106>
schema:inLanguage"en"
schema:isPartOf
schema:name"The r-unit at 320 and 160 Mev"
schema:numberOfPages"5"
schema:publication
schema:publisher
wdrs:describedby

Content-negotiable representations

Close Window

Por favor, conecte-se ao WorldCat 

Não tem uma conta? Você pode facilmente criar uma conta gratuita.