Use of pedometer and Internet-mediated walking program in patients with chronic obstructive pulmonary disease.
閉じる資料のプレビュー
確認中…

Use of pedometer and Internet-mediated walking program in patients with chronic obstructive pulmonary disease.

著者: ML Moy 所属: Rehabilitation Research and Development Service, Veterans Health Administration, Department of Veteran Affairs (VA), Washington, DC, USA. marilyn.moy@va.govAW JanneyHQ NguyenKR MatthessM Cohenすべての著者
エディション/フォーマット: 記事/論文 記事/論文 : English
出版:Journal of rehabilitation research and development, 2010; 47(5): 485-96
データベース::MEDLINE®/ PubMed®
その他のデータベース: ElsevierArticleFirst
概要:
We evaluated an Internet-mediated, pedometer-based program to promote walking in chronic obstructive pulmonary disease (COPD). First, we assessed the accuracy of the Omron HJ-720ITC pedometer (OMRON Healthcare, Inc; Bannockburn, Illinois) in 51 persons with COPD. The Bland-Altman plot showed a median difference of 3 steps (5th and 95th quintiles, -8.0 and 145.0, respectively). We calculated percent difference =  続きを読む
評価:

評価数: 1 件 1 件のレビュー

関連情報:

 

&AllPage.SpinnerRetrieving;

オフラインで入手

&AllPage.SpinnerRetrieving; この資料の所蔵館を検索中…

詳細

ドキュメントの種類: 記事
すべての著者/寄与者: ML Moy 所属: Rehabilitation Research and Development Service, Veterans Health Administration, Department of Veteran Affairs (VA), Washington, DC, USA. marilyn.moy@va.gov; AW Janney; HQ Nguyen; KR Matthess; M Cohen; E Garshick; CR Richardson
ISSN:0748-7711
言語注記: English
固有識別子 673261352
受賞歴:

概要:

We evaluated an Internet-mediated, pedometer-based program to promote walking in chronic obstructive pulmonary disease (COPD). First, we assessed the accuracy of the Omron HJ-720ITC pedometer (OMRON Healthcare, Inc; Bannockburn, Illinois) in 51 persons with COPD. The Bland-Altman plot showed a median difference of 3 steps (5th and 95th quintiles, -8.0 and 145.0, respectively). We calculated percent difference = ([manual - Omron step counts]/manual step counts) x 100. Variability in percent difference occurred at the lowest usual walking speeds. At speeds 80% of the manual step counts in 20 of the 23 persons with walking speed 0.94 m/s. Accuracy is more variable at lower speeds, but the Omron captures more than 80% of manual step counts in most persons.In this preliminary study, an Internet-mediated walking program using the Omron significantly increased step counts in COPD.

レビュー

ユーザーレビュー

WorldCatユーザーのレビュー (1)

Best Acer Book User Book For Sale

by OmronPedometerSale (投稿: 2011-01-13) 良い パーマリンク

good book for

<h3 class="item-title"><a href="../../../oclc/673261352">Use of pedometer</a> very good price for buy I love this book</h3>

read it now!

  • このレビューは役に立ちましたか?
  •   
GoodReadsのレビューを取得中…
DOGObooksのレビューを取得中…

タグ

すべてのユーザーのタグ (11)

人気のタグを表示: タグリスト | タグクラウド

リクエストの確認

あなたは既にこの資料をリクエストしている可能性があります。このリクエストを続行してよろしければ、OK を選択してください。

リンクデータ

ウインドウを閉じる

WorldCatにログインしてください 

アカウントをお持ちではないですか?簡単に 無料アカウントを作成することができます。.