pular para conteúdo
Use of pedometer and Internet-mediated walking program in patients with chronic obstructive pulmonary disease.
FecharVer prévia deste item
Checando...

Use of pedometer and Internet-mediated walking program in patients with chronic obstructive pulmonary disease.

Autor: ML Moy Afiliação: Rehabilitation Research and Development Service, Veterans Health Administration, Department of Veteran Affairs (VA), Washington, DC, USA. marilyn.moy@va.govAW JanneyHQ NguyenKR MatthessM CohenTodos os autores
Edição/Formato Artigo Artigo : Inglês
Publicação:Journal of rehabilitation research and development, 2010; 47(5): 485-96
Base de Dados:De MEDLINE®/PubMed®, uma base de dados da Biblioteca Nacional de Medicina dos EUA.
Outras Bases de Dados: ElsevierArticleFirst
Resumo:
We evaluated an Internet-mediated, pedometer-based program to promote walking in chronic obstructive pulmonary disease (COPD). First, we assessed the accuracy of the Omron HJ-720ITC pedometer (OMRON Healthcare, Inc; Bannockburn, Illinois) in 51 persons with COPD. The Bland-Altman plot showed a median difference of 3 steps (5th and 95th quintiles, -8.0 and 145.0, respectively). We calculated percent difference =  Ler mais...
Classificação:

baseado em 1 classificação(ões) 1 com uma crítica

Mais como este

 

&AllPage.SpinnerRetrieving;

Encontrar uma cópia na biblioteca

&AllPage.SpinnerRetrieving; Encontrando bibliotecas que possuem este item...

Detalhes

Tipo de Documento: Artigo
Todos os Autores / Contribuintes: ML Moy Afiliação: Rehabilitation Research and Development Service, Veterans Health Administration, Department of Veteran Affairs (VA), Washington, DC, USA. marilyn.moy@va.gov; AW Janney; HQ Nguyen; KR Matthess; M Cohen; E Garshick; CR Richardson
ISSN:0748-7711
Nota do Idioma: English
Idenficador Único: 673261352
Prêmios:

Resumo:

We evaluated an Internet-mediated, pedometer-based program to promote walking in chronic obstructive pulmonary disease (COPD). First, we assessed the accuracy of the Omron HJ-720ITC pedometer (OMRON Healthcare, Inc; Bannockburn, Illinois) in 51 persons with COPD. The Bland-Altman plot showed a median difference of 3 steps (5th and 95th quintiles, -8.0 and 145.0, respectively). We calculated percent difference = ([manual - Omron step counts]/manual step counts) x 100. Variability in percent difference occurred at the lowest usual walking speeds. At speeds 80% of the manual step counts in 20 of the 23 persons with walking speed 0.94 m/s. Accuracy is more variable at lower speeds, but the Omron captures more than 80% of manual step counts in most persons.In this preliminary study, an Internet-mediated walking program using the Omron significantly increased step counts in COPD.

Críticas

Críticas contribuídas por usuários

Críticas de Usuários WorldCat (1)

Best Acer Book User Book For Sale

por OmronPedometerSale (Usuário WorldCat publicado 2011-01-13) Bom Permalink

good book for

<h3 class="item-title"><a href="../../../oclc/673261352">Use of pedometer</a> very good price for buy I love this book</h3>

read it now!

  • Esta crítica te ajudou?
  •   
Recuperando críticas GoodReas...
Recuperando comentários DOGObooks

Etiquetas

Etiquetas de todos os usuários (11)

Ver as etiquetas mais populares como: lista de etiquetas | nuvem de etiquetas

Confirmar esta solicitação

Você já pode ter solicitado este item. Por favor, selecione Ok se gostaria de proceder com esta solicitação de qualquer forma.

Close Window

Por favor, conecte-se ao WorldCat 

Não tem uma conta? Você pode facilmente criar uma conta gratuita.